MDT Inputs

Sort By:  
Analog In-/Output 2-fold, Flush mounted, input voltage 0-12V/2-10V or current loop 0-20mA/4-20mA, output voltage 0-10V
100.17€
Analog In-/Output 4-fold, input voltage 0-12V/2-10V or current loop 0-20mA/4-20mA, output voltage 0-10V
133.03€
Universal Interface 2-fold Flush mounted, for floating contacts, with LED output
32.86€
Universal Interface 2-fold Flush mounted, for 230VAC signals
61.48€
Binary Inputs 4-fold, 2SU MDRC, for floating contacts
115.54€
Universal Interface 4-fold Flush mounted, for floating contacts, with LED output
45.04€
Binary Inputs 4-fold, 2SU MDRC, Inputs 24VAC/DC
115.54€
Binary Inputs 4-fold, 2SU MDRC, Inputs 230VAC
115.54€
Universal Interface 6-fold Flush mounted, for floating contacts, with LED output
57.77€
Binary Inputs 8-fold, 4SU MDRC, for floating contacts
156.35€
Binary Inputs 8-fold, 4SU MDRC, Inputs 24VAC/DC
156.35€
Binary Inputs 8-fold, 4SU MDRC, Inputs 230VAC
156.35€
Binary Inputs 16-fold, 8SU MDRC, for floating contacts
239.56€
Binary Inputs 16-fold, 4SU MDRC, Inputs 24VAC/DC
239.56€
Binary Inputs 16-fold, 4SU MDRC, Inputs 230VAC
239.56€
Binary Inputs 32-fold, 12SU MDRC, for potential free contacts
346.09€
AIO-0210V.xx (042.013)
AIO Analog IN-/Output
Description: The MDT Analog In-/Output is suitable to control devices with 0-10V inputs and to catch 0-20mA/0-10V measurement data. All channels are gavanically isolated from the KNX bus and can be configured independently from each other as input or output. The input voltage range is from 0-10V or from 2-10V, optionally the inputs can be operated as current loop with 0-20mA or 4-20mA. Each input can be parameterized individually with the ETS.

Για περισσότερες πληροφορίες στα υλικά MDT www.mdt-knx.gr

  • Production in Germany, certified according to ISO 9001
  • Each channel can be configured indepentently (In-/output)
  • In/outputs are galvanically isolated from the bus
  • In/outputs are galvanically connected together
  • Voltage for output operation is generated inside the actuator
  • No external power supply required
  • Input operation 0-10V/2-10V or 0-20mA/4-20mA (switchable)
    - Conversation of measuring unit and DPT can be parameterized
    - Min/max function, wire breakage detection
    - Threshold and traffic light function
  • Output functions 0-10V:
    - Control by 1Byte, 2Byte float or 1Bit objects
    - Day/night function to limit control value
    - Emergency mode if given value fails
  • Flush mounted in socket
  • Dimensions (W x H x D): 41mm x 41mm x 22mm
  • Integrated bus coupling unit

Analog In-/Output 2-fold, Flush mounted, input voltage 0-12V/2-10V or current loop 0-20mA/4-20mA, output voltage 0-10V
100.17€
AIO-0410V.xx (042.014)
AIO Analog IN-/Output
Description: The MDT Analog In-/Output is suitable to control devices with 0-10V inputs and to catch 0-20mA/0-10V measurement data. All channels are gavanically isolated from the KNX bus and can be configured independently from each other as input or output. The input voltage range is from 0-10V or from 2-10V, optionally the inputs can be operated as current loop with 0-20mA or 4-20mA. Each input can be parameterized individually with the ETS.

Για περισσότερες πληροφορίες στα υλικά MDT www.mdt-knx.gr

  • Production in Germany, certified according to ISO 9001
  • Each channel can be configured indepentently (In-/output)
  • In/outputs are galvanically isolated from the bus
  • In/outputs are galvanically connected together
  • Voltage for output operation is generated inside the actuator
  • No external power supply required
  • Input operation 0-10V/2-10V or 0-20mA/4-20mA (switchable)
    - Conversation of measuring unit and DPT can be parameterized
    - Min/max function, wire breakage detection
    - Threshold and traffic light function
  • Output functions 0-10V:
    - Control by 1Byte, 2Byte float or 1Bit objects
    - Day/night function to limit control value
    - Emergency mode if given value fails
  • Flush mounted in socket
  • Dimensions (W x H x D): 41mm x 41mm x 22mm
  • Integrated bus coupling unit

Analog In-/Output 4-fold, input voltage 0-12V/2-10V or current loop 0-20mA/4-20mA, output voltage 0-10V
133.03€
BE-02001.xx (042.009)
BE Universal Interface to read out floating contacts
Description: The inputs of the MDT Universal Interface react depending on their programmed parameters and send a telegram on the KNX bus. You can connect conventional push-buttons or auxiliary contacts (e.g. door and window contacts) to the device.

Για περισσότερες πληροφορίες στα υλικά MDT www.mdt-knx.gr

  • Production in Germany, certified according to ISO 9001
  • To connect push-buttons or auxiliary contacts
  • Each output can be set as 1,5mA low current output for LED
  • (Only for Universal Interface with floating contacts)
  • 4 integrated logical modules, sending od scenes
  • NO or NC contact operation, programmable length of button push
  • Operation of blinds and shutters, 1 and 2 button operation
  • Forced setting function for each output
  • Operation with short/long button push and 2 objects
  • Counting of pulses
  • Cyclical sending of contact state programmable
  • Flush mounted (length of connection cables: 22cm)
  • Dimensions (W x H x D): 41mm x 41mm x 12mm
  • Integrated bus coupling unit

Universal Interface 2-fold Flush mounted, for floating contacts, with LED output
32.86€
BE-02230.xx (042.012)
BE Universal Interface to read out floating contacts
Description: The inputs of the MDT Universal Interface react depending on their programmed parameters and send a telegram on the KNX bus. You can connect conventional push-buttons or auxiliary contacts (e.g. door and window contacts) to the device.

Για περισσότερες πληροφορίες στα υλικά MDT www.mdt-knx.gr

  • Production in Germany, certified according to ISO 9001
  • To connect push-buttons or auxiliary contacts
  • Each output can be set as 1,5mA low current output for LED
  • (Only for Universal Interface with floating contacts)
  • 4 integrated logical modules, sending od scenes
  • NO or NC contact operation, programmable length of button push
  • Operation of blinds and shutters, 1 and 2 button operation
  • Forced setting function for each output
  • Operation with short/long button push and 2 objects
  • Counting of pulses
  • Cyclical sending of contact state programmable
  • Flush mounted (length of connection cables: 22cm)
  • Dimensions (W x H x D): 41mm x 41mm x 12mm
  • Integrated bus coupling unit

Universal Interface 2-fold Flush mounted, for 230VAC signals
61.48€
BE-04000.xx (042.001)
BE Binary Inputs DIN RAIL to read out floating contacts
Description: The MDT Binary Input is available in 3 versions, input detection of 24VAC/DC signals, input detection of 230VAC signals and reading out of floating contacts. The Binary Input reacts depending on its programmed parameters and sends a telegram on the KNX bus.

Για περισσότερες πληροφορίες στα υλικά MDT www.mdt-knx.gr

  • Production in Germany, certified according to ISO 9001
  • To connect push-buttons or window/auxiliary contacts
  • 4 integrated logical modules,e.g. interpretation of the inputs
    (e.g. window closed or sending second object)
  • NO or NC contact operation, sending of contact state
  • Operation of blinds and shutters, 1 and 2 button operation
  • Forced setting function for each output
  • Scenes, block communication object for each channel
  • Operation with short/long button push and 2 objects
  • Counting of pulses, suitable for 30ms S0 pulses
  • Cyclical sending, sending after reset
  • Internal contact voltage 12V

Binary Inputs 4-fold, 2SU MDRC, for floating contacts
115.54€
BE-04001.xx (042.010)
BE Universal Interface to read out floating contacts
Description: The inputs of the MDT Universal Interface react depending on their programmed parameters and send a telegram on the KNX bus. You can connect conventional push-buttons or auxiliary contacts (e.g. door and window contacts) to the device.

Για περισσότερες πληροφορίες στα υλικά MDT www.mdt-knx.gr

  • Production in Germany, certified according to ISO 9001
  • To connect push-buttons or auxiliary contacts
  • Each output can be set as 1,5mA low current output for LED
  • (Only for Universal Interface with floating contacts)
  • 4 integrated logical modules, sending od scenes
  • NO or NC contact operation, programmable length of button push
  • Operation of blinds and shutters, 1 and 2 button operation
  • Forced setting function for each output
  • Operation with short/long button push and 2 objects
  • Counting of pulses
  • Cyclical sending of contact state programmable
  • Flush mounted (length of connection cables: 22cm)
  • Dimensions (W x H x D): 41mm x 41mm x 12mm
  • Integrated bus coupling unit

Universal Interface 4-fold Flush mounted, for floating contacts, with LED output
45.04€
BE-04024.xx (042.004)
BE Binary Inputs DIN RAIL to read out floating contacts
Description: The MDT Binary Input is available in 3 versions, input detection of 24VAC/DC signals, input detection of 230VAC signals and reading out of floating contacts. The Binary Input reacts depending on its programmed parameters and sends a telegram on the KNX bus.

Για περισσότερες πληροφορίες στα υλικά MDT www.mdt-knx.gr

  • Production in Germany, certified according to ISO 9001
  • To connect push-buttons or window/auxiliary contacts
  • 4 integrated logical modules,e.g. interpretation of the inputs
    (e.g. window closed or sending second object)
  • NO or NC contact operation, sending of contact state
  • Operation of blinds and shutters, 1 and 2 button operation
  • Forced setting function for each output
  • Scenes, block communication object for each channel
  • Operation with short/long button push and 2 objects
  • Counting of pulses, suitable for 30ms S0 pulses
  • Cyclical sending, sending after reset
  • Internal contact voltage 12V

Binary Inputs 4-fold, 2SU MDRC, Inputs 24VAC/DC
115.54€
BE-04230.xx (042.006)
BE Binary Inputs DIN RAIL to read out floating contacts
Description: The MDT Binary Input is available in 3 versions, input detection of 24VAC/DC signals, input detection of 230VAC signals and reading out of floating contacts. The Binary Input reacts depending on its programmed parameters and sends a telegram on the KNX bus.

Για περισσότερες πληροφορίες στα υλικά MDT www.mdt-knx.gr

  • Production in Germany, certified according to ISO 9001
  • To connect push-buttons or window/auxiliary contacts
  • 4 integrated logical modules,e.g. interpretation of the inputs
    (e.g. window closed or sending second object)
  • NO or NC contact operation, sending of contact state
  • Operation of blinds and shutters, 1 and 2 button operation
  • Forced setting function for each output
  • Scenes, block communication object for each channel
  • Operation with short/long button push and 2 objects
  • Counting of pulses, suitable for 30ms S0 pulses
  • Cyclical sending, sending after reset
  • Internal contact voltage 12V

Binary Inputs 4-fold, 2SU MDRC, Inputs 230VAC
115.54€
BE-06001.xx (042.011)
BE Universal Interface to read out floating contacts
Description: The inputs of the MDT Universal Interface react depending on their programmed parameters and send a telegram on the KNX bus. You can connect conventional push-buttons or auxiliary contacts (e.g. door and window contacts) to the device.

Για περισσότερες πληροφορίες στα υλικά MDT www.mdt-knx.gr

  • Production in Germany, certified according to ISO 9001
  • To connect push-buttons or auxiliary contacts
  • Each output can be set as 1,5mA low current output for LED
  • (Only for Universal Interface with floating contacts)
  • 4 integrated logical modules, sending od scenes
  • NO or NC contact operation, programmable length of button push
  • Operation of blinds and shutters, 1 and 2 button operation
  • Forced setting function for each output
  • Operation with short/long button push and 2 objects
  • Counting of pulses
  • Cyclical sending of contact state programmable
  • Flush mounted (length of connection cables: 22cm)
  • Dimensions (W x H x D): 41mm x 41mm x 12mm
  • Integrated bus coupling unit

Universal Interface 6-fold Flush mounted, for floating contacts, with LED output
57.77€
BE-08000.xx (042.002)
BE Binary Inputs DIN RAIL to read out floating contacts
Description: The MDT Binary Input is available in 3 versions, input detection of 24VAC/DC signals, input detection of 230VAC signals and reading out of floating contacts. The Binary Input reacts depending on its programmed parameters and sends a telegram on the KNX bus.

Για περισσότερες πληροφορίες στα υλικά MDT www.mdt-knx.gr

  • Production in Germany, certified according to ISO 9001
  • To connect push-buttons or window/auxiliary contacts
  • 4 integrated logical modules,e.g. interpretation of the inputs
    (e.g. window closed or sending second object)
  • NO or NC contact operation, sending of contact state
  • Operation of blinds and shutters, 1 and 2 button operation
  • Forced setting function for each output
  • Scenes, block communication object for each channel
  • Operation with short/long button push and 2 objects
  • Counting of pulses, suitable for 30ms S0 pulses
  • Cyclical sending, sending after reset
  • Internal contact voltage 12V

Binary Inputs 8-fold, 4SU MDRC, for floating contacts
156.35€
BE-08024.xx (042.015)
BE Binary Inputs DIN RAIL to read out floating contacts
Description: The MDT Binary Input is available in 3 versions, input detection of 24VAC/DC signals, input detection of 230VAC signals and reading out of floating contacts. The Binary Input reacts depending on its programmed parameters and sends a telegram on the KNX bus.

Για περισσότερες πληροφορίες στα υλικά MDT www.mdt-knx.gr

  • Production in Germany, certified according to ISO 9001
  • To connect push-buttons or window/auxiliary contacts
  • 4 integrated logical modules,e.g. interpretation of the inputs
    (e.g. window closed or sending second object)
  • NO or NC contact operation, sending of contact state
  • Operation of blinds and shutters, 1 and 2 button operation
  • Forced setting function for each output
  • Scenes, block communication object for each channel
  • Operation with short/long button push and 2 objects
  • Counting of pulses, suitable for 30ms S0 pulses
  • Cyclical sending, sending after reset
  • Internal contact voltage 12V

Binary Inputs 8-fold, 4SU MDRC, Inputs 24VAC/DC
156.35€
BE-08230.xx (042.007)
BE Binary Inputs DIN RAIL to read out floating contacts
Description: The MDT Binary Input is available in 3 versions, input detection of 24VAC/DC signals, input detection of 230VAC signals and reading out of floating contacts. The Binary Input reacts depending on its programmed parameters and sends a telegram on the KNX bus.

Για περισσότερες πληροφορίες στα υλικά MDT www.mdt-knx.gr

  • Production in Germany, certified according to ISO 9001
  • To connect push-buttons or window/auxiliary contacts
  • 4 integrated logical modules,e.g. interpretation of the inputs
    (e.g. window closed or sending second object)
  • NO or NC contact operation, sending of contact state
  • Operation of blinds and shutters, 1 and 2 button operation
  • Forced setting function for each output
  • Scenes, block communication object for each channel
  • Operation with short/long button push and 2 objects
  • Counting of pulses, suitable for 30ms S0 pulses
  • Cyclical sending, sending after reset
  • Internal contact voltage 12V

Binary Inputs 8-fold, 4SU MDRC, Inputs 230VAC
156.35€
BE-16000.xx (042.003)
BE Binary Inputs DIN RAIL to read out floating contacts
Description: The MDT Binary Input is available in 3 versions, input detection of 24VAC/DC signals, input detection of 230VAC signals and reading out of floating contacts. The Binary Input reacts depending on its programmed parameters and sends a telegram on the KNX bus.

Για περισσότερες πληροφορίες στα υλικά MDT www.mdt-knx.gr

  • Production in Germany, certified according to ISO 9001
  • To connect push-buttons or window/auxiliary contacts
  • 4 integrated logical modules,e.g. interpretation of the inputs
    (e.g. window closed or sending second object)
  • NO or NC contact operation, sending of contact state
  • Operation of blinds and shutters, 1 and 2 button operation
  • Forced setting function for each output
  • Scenes, block communication object for each channel
  • Operation with short/long button push and 2 objects
  • Counting of pulses, suitable for 30ms S0 pulses
  • Cyclical sending, sending after reset
  • Internal contact voltage 12V

Binary Inputs 16-fold, 8SU MDRC, for floating contacts
239.56€
BE-16024.xx (042.005)
BE Binary Inputs DIN RAIL to read out floating contacts
Description: The MDT Binary Input is available in 3 versions, input detection of 24VAC/DC signals, input detection of 230VAC signals and reading out of floating contacts. The Binary Input reacts depending on its programmed parameters and sends a telegram on the KNX bus.

Για περισσότερες πληροφορίες στα υλικά MDT www.mdt-knx.gr

  • Production in Germany, certified according to ISO 9001
  • To connect push-buttons or window/auxiliary contacts
  • 4 integrated logical modules,e.g. interpretation of the inputs
    (e.g. window closed or sending second object)
  • NO or NC contact operation, sending of contact state
  • Operation of blinds and shutters, 1 and 2 button operation
  • Forced setting function for each output
  • Scenes, block communication object for each channel
  • Operation with short/long button push and 2 objects
  • Counting of pulses, suitable for 30ms S0 pulses
  • Cyclical sending, sending after reset
  • Internal contact voltage 12V

Binary Inputs 16-fold, 4SU MDRC, Inputs 24VAC/DC
239.56€
BE-16230.xx (042.008)
BE Binary Inputs DIN RAIL to read out floating contacts
Description: The MDT Binary Input is available in 3 versions, input detection of 24VAC/DC signals, input detection of 230VAC signals and reading out of floating contacts. The Binary Input reacts depending on its programmed parameters and sends a telegram on the KNX bus.

Για περισσότερες πληροφορίες στα υλικά MDT www.mdt-knx.gr

  • Production in Germany, certified according to ISO 9001
  • To connect push-buttons or window/auxiliary contacts
  • 4 integrated logical modules,e.g. interpretation of the inputs
    (e.g. window closed or sending second object)
  • NO or NC contact operation, sending of contact state
  • Operation of blinds and shutters, 1 and 2 button operation
  • Forced setting function for each output
  • Scenes, block communication object for each channel
  • Operation with short/long button push and 2 objects
  • Counting of pulses, suitable for 30ms S0 pulses
  • Cyclical sending, sending after reset
  • Internal contact voltage 12V

Binary Inputs 16-fold, 4SU MDRC, Inputs 230VAC
239.56€
BE-32000.xx (042.016)
BE Binary Inputs DIN RAIL to read out floating contacts
Description: The MDT Binary Input is available in 3 versions, input detection of 24VAC/DC signals, input detection of 230VAC signals and reading out of floating contacts. The Binary Input reacts depending on its programmed parameters and sends a telegram on the KNX bus.

Για περισσότερες πληροφορίες στα υλικά MDT www.mdt-knx.gr

  • Production in Germany, certified according to ISO 9001
  • To connect push-buttons or window/auxiliary contacts
  • New multi touch function, sends up to 4 values/DPTs
    on the same or diffrent objects
  • Innovative group control with long/extra long button press
  • 4 integrated logical modules,e.g. interpretation of the inputs
    (e.g. window closed or sending second object)
  • NO or NC contact operation, sending contact status
  • Operation of blinds and shutters, 1 and 2 button operation
  • Forced setting function for each output
  • Scenes, block communication object for each channel
  • Operation with short/long button push and 2 objects
  • Integrated pulse and switching counters with extensive counter functions
    (suitable for 30ms S0 pulses)
  • Cyclical sending, sending after reset
  • Internally generated contact voltage of 12V

Binary Inputs 32-fold, 12SU MDRC, for potential free contacts
346.09€
Per Page      1 - 16 of 16
  • 1